The CO2 Differentiator

As refrigerant choices keep shifting across commercial and industrial cooling, one option keeps coming up in nearly every conversation about the future: carbon dioxide, or R-744. It isn’t new—it predates modern synthetic refrigerants by more than a century—but it behaves so differently from the fluids most technicians and engineers trained on that it’s worth walking through what sets it apart. What really is the CO2 differentiator?

Part 2 of 3 in our series on the transition to low-GWP refrigerants from Century Refrigeration. See our previous post on Regulatory Rollbacks.

Background of green trees with text that says, "What Makes CO2 Different?"

An Old Refrigerant Having a Second Act 

CO2 has been used as a refrigerant since the 1860s and was common in marine and industrial cooling well into the early 20th century, before being displaced by CFCs, HCFCs, and eventually HFCs—synthetic refrigerants that were simply easier to work with given the equipment and pressure ratings of the time. It reemerged over the last quarter-century, championed by Norwegian engineer Gustav Lorentzen in the 1990s, as global warming potential became the dominant design constraint once again. Today it’s one of the fastest-growing refrigerant choices for new commercial and industrial systems worldwide. 

A CO2 Differentiator: A GWP of 1 

Global warming potential measures how much heat a gas traps in the atmosphere relative to CO2 over a set time horizon. CO2 itself is the reference point, with a GWP of exactly 1. Compare that to the refrigerants common in industrial and commercial refrigeration today, and the gap is enormous: 

Refrigerant GWP (100-yr) ASHRAE 34 Safety Class 
R-404A ~3,922 A1 (non-flammable) 
R-134a ~1,430 A1 (non-flammable) 
R-410A ~2,088 A1 (non-flammable) 
R-454C ~146 A2L (flammable) 
R455A ~146 A2L (flammable) 
R-290 (propane) ~3 A3 (flammable) 
R-744 (CO2) 1 A1 (non-flammable) 

CO2 also carries an ozone depletion potential (ODP) of zero, same as the HFCs it’s competing with, but with a fraction of the climate impact. And because it isn’t an HFC at all, it falls entirely outside the AIM Act’s allowance allocation system—its supply isn’t capped, allocated, or subject to the same shrinking-quota price pressure that legacy refrigerants will keep facing as the phasedown advances. For an operator planning refrigerant strategy a decade out, it’s a future-proof solution for both regulatory and market risk. 

Safety Classification: A1, But Not Risk-Free 

ASHRAE Standard 34 classifies CO2 as A1—lower toxicity, non-flammable—the same top safety tier as R-134a, and a meaningful advantage over ammonia (toxic, class B2L) and propane (flammable, class A3). That classification matters enormously in practice, since A2L and A3 refrigerants face charge-size limits and occupancy-based installation restrictions that A1 refrigerants generally don’t. 

That said, CO2 isn’t without hazards. It’s an asphyxiant at high concentrations in enclosed spaces, which still requires proper ventilation and detection design. And for engineers, the more consequential difference isn’t toxicity or flammability at all, but instead, the important factor is pressure. 

The Pressure Problem (and the Opportunity) 

CO2 reaches its critical point—the temperature and pressure above which it can no longer exist as a distinct liquid and gas—at just 87.8°F and 1,055 psi. Typical high side CO2 refrigeration systems utilize max pressure ratings of 1,305 to 1,885 psi, compared with 450 to 650 psi for the HFC systems most of the industry has built around for decades.  

That pressure difference affects everything: compressors, valves, gaskets, vessels, piping, and even the gauges and recovery equipment technicians carry all have to be rated for a different pressure class entirely. Historically, this factor has been the single biggest barrier to CO2 adoption in the U.S. The barrier hasn’t been the refrigerant itself, but the installed base of equipment and tooling built for much lower pressures. 

But higher pressure isn’t purely a cost. CO2’s vapor density delivers far more refrigeration effect per pound moved and per cubic foot of compressor displacement than traditional refrigerants. In practice, that means smaller compressors and smaller-diameter piping can move the same cooling load. This results in savings in material and footprint that can help offset the cost of higher-pressure-rated components. That’s a CO2 differentiator!

CO2 vs. Its Other Low-GWP Rival: Propane 

Propane (R-290) is the other natural refrigerant getting serious attention, with a GWP near 3. But as an A3-classified flammable refrigerant, it faces strict charge-size limits in most U.S. occupancies, which has largely confined it to smaller, self-contained equipment. For large, centralized industrial-scale systems—cold storage warehouses, food and beverage processing, multi-thousand-pound charge systems —CO2’s non-flammability makes it dramatically easier to permit, insure, and service at scale, even where propane might edge it out in a small point-of-sale cooler. That’s a major reason CO2, not propane, is gaining the most traction in large industrial refrigeration systems in the U.S. right now. 

These are just a few of the reasons that people are choosing CO2 for their industrial and commercial applications—it’s the CO2 differentiator.

Larry Hudson Headshot

Larry Hudson

Century Refrigeration, Senior Product Manager

918.825.7222

Century Refrigeration, a division of RAE Corporation, is engineering these exact realities into our COMDUSTRIAL solutions, designed, engineered, and assembled entirely in Oklahoma. In our next post, we’ll open up a transcritical system and walk through how it runs.